Replacement Temperature Monitor and Flame Viewing System for Ruston TA Series Gas turbines
Part Number: PS-5450-01

This unit utilizes a fail-safe Dynalco digital temperature monitor to provide continuous scanning of all existing temperature and speed changes, indicating individual thermocouple values and T-Max. It provides relay outputs on T-Max for shutdown, warning, max. continuous temperature and engine hot signals. The unit comes with two set points for each alarm and shutdown to differentiate between start and running conditions. The unit scans existing signals and cold junction compensated before comparing to customer programmed alarm and shutdown set points. The unit installs on top of the existing cabinet and thermocouple extension cable is provided for the link to the junction box.

The fail-safe flame viewer utilizes a Honeywell u.v. flame scanner which produces a ripple on the steady DC power which is detected by the amplifier. A relay output indicates two lamps and sends logic signals for control functions.

The user will find that in day to day operation, nothing has changed, but the additional information is excellent for trouble-shooting problems and extending engine life.

With correctly sized wiring the unit can operate up to 300 m from the turbine and the flame sensor is designed to withstand temperatures up to 300 deg. F and vibration up to 2000 Hz.




The unit consists of a 19" x 21" x 12" rack mounted assembly in a rugged 21" x 21" x 12" steel case. The temperature monitor control panel (PS-5410-01) is mounted in the 19" rack. The relay and power modules are mounted in the cabinet. The control panel is side hinge mounted for ease of servicing. All inputs / outputs are connected to the terminal strip in the cabinet.

The flame viewing system (PS-1080-04) has two selections, a viewing head (PS-1091-02) mounted on the engine with a custom built stainless steel adaptor, and a control unit (PS-1082-04) for 24 VDC, 28VDC, and flame on indicators. It also includes a press to test button. The control module is removable for field servicing and contains an amplifier, power supply and relay card.

 

 

     U.S.A(English):                 President: Andrew Jackson

Main Office|16810 Barker Springs Road, Suite 210 | Houston, Texas 77084, U.S.A.
Phone 281-647-9770 | FAX 281-647-0801 | www.patented-systems.com

     South America(Spanish):           Agent: Francisco Gomez      Global Oil, S.A.

Afganistan #72 6th floor| Quito, Ecuador| Phone 593-2-246-6009
Fax 593-2-244-7006|Mobile 593-9-924-2124|sales@globaloilsupply.com

     Mexico(Spanish):                Agent: Miguel Inclán

Aguascalientes #12 Despacho 101-A, Colonia Roma|Del. Cuauhtemoc,06760 Mexico D.F.
Phone/Fax (55) 5574-9697| poupee321@yahoo.com

  Sultanate of Oman(Arabic/English): Agent: W.J. Towell & Co. LLC- Engineering Division

Contact: Balaji Srinivasan(Gen. Mgr.)|P.O. Box 1040, RUWI 112|Sultanate of Oman
Phone (968) 7715481 or 7714984|Fax (968) 7710422| wjttsd@omantel.net.om

Please be advised that Patented Systems Inc is not an authorized dealer of Alstom.  Please be further advised that the terms "TA" and "TB" are tradnames of Alstom.

[info@patented-systems.com]
[Search]  [Site Menu]

Ruston gas turbines & engines, EGT & Alstom gas turbines, European gas turbines. Gas turbine service, repair & parts, new & used. Sales company that specializes in Ruston, EGT and Alstom gas turbines.